Nortel DMS-100 Series Maintenance Manual page 319

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

26
CAUTION
If you do not allow the time required for the system to
clear the alarm, a false alarm indication can occur.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
To identify the P-side links that have faults, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
LINK
0:
RMM 0 0;CAP MS;STATUS:SysB,;MSGCOND: CLS
LINK
1:
RMM 0 1;CAP MS;STATUS:SysB,;MSGCOND: CLS
LINK
2:
ESA 0 0;CAP
LINK
4:
ESA 0 1;CAP
27
To busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that has faults identified in step 26
28
To test the ManB link, type
>TST LINK link_no
and press the Enter key.
If test
passes
fails
S;STATUS:
S;STATUS:
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-83
major
OK,;MSGCOND: OPN
OK,;MSGCOND: OPN
Do
step 29
step 35
RMM
(continued)