Nortel DMS-100 Series Maintenance Manual page 396

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-30 Card replacement procedures
NT2X11
NT2X11
RMM
RMM
(continued)
(end)
8
9
10
11
12
13
14
15
297-8211-550 Standard 05.01 August 1999
Return to service the circuit tested by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Place the untested circuit in the control position by typing
>NEXT 1
and pressing the Enter key.
Test the circuit by typing
>TST
If TST
passed
failed
Return to service and clear the trunk tesr position by typing
>RTS;NEXT
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 15.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have completed this procedure.
Do
step 9
step 14
Do
step 11
step 14