Nortel DMS-100 Series Maintenance Manual page 382

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-16 Card replacement procedures
NT2X09
RMM
(continued)
Replacing an NT2X09 in an RMM
At your Current Location
1
2
At the MAP terminal
3
4
5
At the RMM
6
297-8211-550 Standard 05.01 August 1999
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from the Alarm Clearing Procedures , go
to step 6. Otherwise, continue with step 3.
Access the peripheral module (PM) level of the MAP display by typing
>MAPCI;MTC;PM
and pressing the Enter key.
Post the RMM by typing
>POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
Example of a MAP response:
SysB
PM
0
RMM
1
RMM
0
SysB
Busy the RMM by typing
>BSY
and pressing the Enter key.
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point at the top of each equipment rack,
(Bay 0, 1, 2, and 3), while handling circuit cards. This
protects the cards against damage caused by static
electricity.
ManB
Offl
2
2
0
1
CBsy
ISTb
0
7
0
0
InSv
21
6