file_name is the name of the SLM disk volume containing the file to be loaded,
obtained in step 21.
24
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
25
Reload the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
If
load failed
load passed
26
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM busied in step 5 (0 or 1)
If RTS
passed
failed
27
Send any faulty cards for repair according to local procedure.
28
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 31.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-109
LCM
Do
step 29
step 26
Do
step27
step29
NT6X51
(continued)

Advertisement

Table of Contents
loading