Nortel DMS-100 Series Maintenance Manual page 384

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-18 Card replacement procedures
NT2X09
RMM
(continued)
12
13
14
At the MAP terminal
15
16
17
18
19
20
297-8211-550 Standard 05.01 August 1999
Determine the type of device where the RMM load files are located.
If load files are located on
tape
IOC disk
SLM disk
Locate the tape that contains the PM load files.
Mount the tape on a magnetic tape drive.
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 28.
From office records, determine and note the number of the input/output
controller (IOC) disk and the number of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DSKUT
and pressing the Enter key.
Do
step13
step19
step24

Advertisement