Nortel DMS-100 Series Maintenance Manual page 31

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Recommended NT6X21AD S1 DIP switch settings
Recommended
application
switch position
ON
0dB
P-phone sets
long loop:
19–24dB EML
P-phone sets
medium loop:
17–19dB EML
P-phone sets
medium loop:
4–17dB EML
P-phone sets
short loops:
0–4dB EML
Northern
Telecom
UDLCs
Other vendors
UDLCs
6X21AC
equivalent
mode
Note: dB=decibel
NL = non-loaded
9+2=loaded (900 ohm + 2.16 micro-farads) network
Vpp=voltage peak to peak
EML= estimated measured loss, as defined in NTP 297-2011-180 BCS35 version 01.02
The following two tables list the two acceptable limits for transhybrid loss
(THL) that depend on the D/A level selected. The NT6X21AD uses the
same diagnostics as the NT6X21AC. This use causes the modification of the
THL limits for diagnostic purposes. The first table is for the NT6X21AC
line card and the second table is for the NT6X21AD line card.
D/A voice
Balance
S1
switch position
OFF
ON
–3.5dB
NL
X
X
X
X
X
X
X
X
X
X
X
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Signaling level
S2
Both
OFF
ON
9+2
1.3Vpp
X
X
X
X
X
Maintenance overview 1-15
S3 and S4
Only
Only
Both
S4 ON
S3 ON
OFF
0.8Vpp
0.6Vpp
0.14Vpp
X
X
X
X
X

Advertisement

Table of Contents
loading

Table of Contents