7-52 Alarm clearing procedures
OPAC (RG)
major
(continued)
Clearing an OPAC (RG) alarm
At your current location
1
2
3
297-8211-550 Standard 05.01 August 1999
Enter this procedure from a peripheral module (PM) system level alarm clearing
procedure step. The step must identify a PM alarm associated with an RLCM
ringing generator fault.
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
To identify the LCM in the OPAC that has faults, type
>DISP STATE LCM ISTB
and press the Enter key.
Example of a MAP display :
ISTb
LCM: 2