Nortel DMS-100 Series Maintenance Manual page 383

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Power down the unit by setting the ON/OFF switch on the power converter
faceplate to the OFF position. Both the converter FAIL LED and FRAME FAIL
lamp on the MSP will be ON.
7
Replace the NT2X09 card using the procedure Replacing a card. When you
have completed the procedure, return here.
8
Power up the RMM unit as follows:
Ensure the converter (NT2X09) is inserted. Set the POWER switch to the ON
position.
9
Press the RESET button on the power converter while setting the circuit
breaker on the MSP to the ON position. Both the CONVERTER FAIL LED and
FRAME FAIL lamp on the MSP will be ON.
10
If you were directed to this procedure from the Alarm Clearing Procedures ,
return to the alarm clearing procedure that directed you here. Otherwise,
continue with step 11.
At the MAP terminal
11
Go to the PM level and post the RMM, if not already posted, and load the RMM
by typing
>PM;POST rmm_no;LOADPM
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
If
message Loadfile not
found in directory is
recieved
load passed
load failed
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-17
RMM
Do
step12
step29
step32
NT2X09
(continued)