Nortel DMS-100 Series Maintenance Manual page 172

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-12 ESA maintenance overview
To verify the firmware load enter the following command at the MAP
display terminal:
>QUERYPM CNTRS
Firmware upgrade
After loadfile verification, the XPM is ready for the firmware upgrade. To
upgrade the firmware use one of the following command string sets:
>LOADFW UPGRADE
Note: By using the LOADFW command with the UPGRADE option, the
firmware is upgraded to the new firmware load.
The next table lists parameters used with the LOADFW command.
LOADFW parameters
Parameter
filename
UPGRADE
ALL
NOWAIT
Note: In this table N/A is an abbreviation for not applicable.
297-8211-550 Standard 05.01 August 1999
Value
n/a
n/a
n/a
n/a
Definition
Name of firmware file. If
the firmware file is not
specified, the firmware
load found in table
XESAINV, field E2LOAD
is used.
Upgrades the PM to the
new firmware load.
UPGRADE is an
optional parameter.
Permits the use of the
LOADFW command on
a posted set of PMs.
ALL is an optional
parameter.
Returns the prompt
before the command is
finished, on-screen
status is not visible.
NOWAIT is an optional
parameter.

Advertisement

Table of Contents
loading

Table of Contents