8
Busy both line subgroups associated with the LCM drawer in which the card is
being replaced by typing
>BSY DRWR
and pressing the Enter key.
Example of a MAP response;
Please confirm ("YES," "Y," "NO," or "N"):
Confirm the system prompt by typing
>YES
and pressing the Enter key.
Go to step 10.
9
Busy both line subgroups associated with the LCM drawer in which the card is
being replaced by typing
>BSY DRWR lsg
and pressing the Enter key.
where
lsg
is one of two line subgroups (0 through 19) associated with the drawer
Example of a MAP response;
LCM REM1 00 0
Please confirm ("YES," "Y," "NO," or "N"):
Confirm the system prompt by typing
>YES
and pressing the Enter key.
Note: Repeat this step for the other line subgroup associated with the line
drawer.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Specific card replacement procedures 8-129
Drwr 4 will be taken out of service
NT6X54
LCM
(continued)