Nortel DMS-100 Series Maintenance Manual page 321

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

32
To return the ManB RMM to service, type
>RTS
and press the Enter key.
If RTS
passed
failed
33
The card list identifies cards with possible faults. Replace the cards one at a
time in the order that this procedure directs.
If you
replaced all the cards on the list
did not replace all the cards on the
list
34
Perform the correct procedure in the Card Replacement Procedures for the
next card on the card list. Complete the card replacement procedure. Go to
step 6.
35
For additional help, contact the next level of support.
36
This procedure is complete. If additional alarms appear, perform the correct
alarm clearing procedures.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-85
major
major
Do
step 36
step 35
Do
step 35
step 34
RMM
RMM
(continued)
(end)