1-8 Maintenance overview
Host interface equipment shelf layout
Slot
01–03
04
05
Note: The LCA contains the NT6X51AB 256 Kbyte processor card. This card
requires the extended memory line concentrating module (XLCM) software load.
LCM control complex cards
The LCM processor (LCMP) card and DCC are common cards in the LCA.
In each LCA, the common cards function identically and are always
provided. A description of the functions of these cards follows.
XLCM processor card
The extended-memory line concentrating module (XLCM) processor card
(NT6X51AB) is in slot 04 of each LCA shelf. The XLCM processor card
connects with the DCC to form the control complex for the LCA. The
XLCM processor card checks sanity and monitors activity. The XLCM
processor also monitors the power and ringing generator functions of the
OPAC.
The XLCM contains 256 kBytes of random access memory (RAM) storage.
The XLCM collects dial pulse digits from subscriber lines. The XLCM
handles messages to and from the host LTC, LGC, or RCC. The maximum
number of lines is 640. The NT6X51AB requires XLCM software loads.
Digroup control card
The DCC (NT6X52) is in slot 05 of the LCA shelf. The DCC allows the
LCA and HIE shelves to communicate.
The DCC provides an interface between the equivalent LCM processor in
the LCA and one link control card (LCC) in the HIE. The DCC provides
this interface through eight DS30A links. The following figure shows this
interface.
297-8211-550 Standard 05.01 August 1999
Abbreviation
NT PEC
NT6X53AA
LCMP
NT6X51AB
DCC
NT6X52AA
NT6X05AA
LSG
Remarks
Power converter. Also contains
ringing and ANI voltage
switching circuits.
XLCM processor card (see note)
Digroup control card
Line drawer
Line subgroup