Nortel DMS-100 Series Maintenance Manual page 438

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-72 Card replacement procedures
NT6X19
LCM
(continued)
Summary of card replacement procedure for NT6X19 card in an LCM
At LTP level, post
the line
Is the line
status ManB?
N
Busy the line
Replace the line
card
Test the line
Did test pass?
N
Obtain assistance
from maintenance
support group
297-8211-550 Standard 05.01 August 1999
Y
Y
Return the line to
service
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Y
Did return to
service pass?
N
Obtain assistance
from maintenance
support group
End of procedure

Advertisement

Table of Contents
loading

Table of Contents