6-6 Recovery Procedures
Recovering an out-of-service OPAC
Recovering an out-of-service OPAC
At the MAP terminal
1
2
3
4
5
6
297-8211-550 Standard 05.01 August 1999
Make sure that the OPAC receives power.
To silence an alarm that remains audible, type:
>MAPCI;MTC;SIL;PM
and press the Enter key.
To identify the OPAC with defects, type:
>DISP STATE CBSY LCM
and press the Enter key.
If response
shows CBsy LCMs are not present
shows CBsy LCMs are present
To post the OPAC with the alarm condition, type:
>POST LCM CBsy
and press the Enter key.
Note the name and number of this OPAC.
To identify central side (C-side) links to the host PM, type:
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
To post the host PM, type:
>POST PM pm_no
and press the Enter key.
where
pm
is a line group controller (LGC), line trunk controller (LTC), or remote
cluster controller (RCC)
pm_no
is the number of the PM
(continued)
Do
step 14
step 4
2; Cap MS; Status: SysB
6; Cap MS; Status: SysB
;MsgCond: CLS
;MsgCond: CLS