13-52 Routine maintenance procedures
GFCI check
OPAC
(continued)
Summary of GFCI check
Press the test
button on the
GFCI outlet
Reset button
pops out?
Y
Press the reset
button on the
GFCI outlet
297-8211-550 Standard 05.01 August 1999
Contact the next
N
level of
maintenance
N
Reset button
pops out?
Y
End of procedure
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.