Nortel DMS-100 Series Maintenance Manual page 231

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Recovering an out-of-service OPAC
22
To post the host XMS-based peripheral module (XPM) links and check link
conditions for slips and framing errors, type:
>POST pm pm_no link_no
and press the Enter key.
where
pm
is a line trunk controller (LGC), line group controller (LTC) or remote
cluster controller (RCC)
pm_no
is the number of the PM (0 to 255)
link_no
is the number of the link associated with the host XPM
(Refer to step 20 display)
Note: Repeat the POST command for each link.
Example MAP response:
N CLASS
SITE LTC CK D ALRM SLIP FRME
0 REMOTE HOST
where
The number that appears under the CK header is the host XPM link number.
Note: This display shows carrier facilities from the host XPM to the OPAC.
Use the detail REM option to check the carrier facilities from the remote site
back to the host XPM.
If link conditions
show a high number of SLIP and
FRME
show a very low number of SLIP
and FRME
23
To post the OPAC with the alarm condition, type:
>PM; POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (0–511)
lcm
is the number of the LCM unit of the OPAC (0 or 1)
1
0 C
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Recovery Procedures 6-11
BER
ES SES STATE
0
0 <–7.
0
Do
Leave the OPAC in ESA. Go to
step 29.
step 23
(continued)
0 INSV

Advertisement

Table of Contents
loading

Table of Contents