Nortel DMS-100 Series Maintenance Manual page 424

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-58 Card replacement procedures
NT3X09
RMM
(continued)
Replacing an NT3X09 in an RMM
At the MAP
1
At your MAP terminal
2
3
4
297-8211-550 Standard 05.01 August 1999
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the trunk test position (TTP) level of the MAP display and post the RMM
that contains the card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
Example of a MAP response:
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
Check the status of the RMM.
If RMM status is
ManB, PMB, RMB
other
Busy the trunks associated with the card to be replaced by typing
>BSY ALL
and pressing the Enter key.
BUSY Q
COM LANG
OTWAON23DA00 2001
OTDA00
Do
step 7
step 4
DIG
STA S R DOT TE R
LO
P_IDL