8-10 Card replacement procedures
NT2X06
RMM
(continued)
At the MAP terminal
11
At the RMM
12
13
14
At the MAP terminal
15
297-8211-550 Standard 05.01 August 1999
Go to the PM level and post the RMM, if not already posted, and load the RMM
by typing
>PM;POST rmm_no;LOADPM
and pressing the Enter key
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
If
message is loadfile not
found in directory
load passed
load failed
Determine the type of device where the PM load files are located.
If load files are located on
tape
IOC disk
SLM disk
Locate the tape that contains the PM load files.
Mount the tape on a magnetic tape drive.
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
Do
step 12
step 29
step 32
Do
step 13
step 19