8-218 Card replacement procedures
NTRX43
MSP
(continued)
NTRX43AA
7
At the rear of the MSP
8
297-8211-550 Standard 05.01 August 1999
b.
Gently pull the circuit card towards you until it clears the shelf.
Ensure the replacement circuit card has the same PEC, including suffix, as the
circuit card just removed.
a.
Align the circuit card with the slots in the shelf and gently slide the circuit
card into the shelf.
b.
Gently but firmly seat the circuit card.
c.
Tighten the captive screw at the top of the circuit card.
Locate the replaced circuit card and reattach the power connectors.