Load the LCM unit by typing
>LOADPM UNIT lcm_unit_no CC
and pressing the Enter key.
where
lcm_unit_no
is the number of the LCM unit to be loadeded
and pressing the Enter key.
If
load passed
load failed
31
Return the busied LCM unit to service by typing the following string:
>RTS UNIT lcm_unit_no
and pressing the Enter key.
where
lcm_unit_no
is the number of the LCM unit to be returned to service
If RTS
passed
failed
32
Send any faulty cards for repair according to local procedure.
33
Record the date card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 35.
34
Obtain further assistance in replacing this card by contacting the personnel
responsible for the next higher level of support.
35
You have completed this procedure. Remove the sign from the active unit and
return to the maintenance procedure that directed you to this card replacement
procedure and continue as directed.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-231
MSP
Do
step 31
step 34
Do
step 32
step 34
NTRX44
NTRX44
MSP
(continued)
(end)