Nortel DMS-100 Series Maintenance Manual page 250

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-14 Alarm clearing procedures
OPAC
critical
(continued)
33
34
35
297-8211-550 Standard 05.01 August 1999
To load the LCM unit, type
>LOADPM UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the OPAC to be loaded (0 or 1)
If the load
is successful
is not successful
To test the LCM unit, type
>TST UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the OPAC to test (0 or 1)
If the test
passes
fails, and the system generates a card list
fails, and the system does not generate a card
list
To attempt to RTS the LCM unit, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the OPAC that must return to service (0 or 1)
If the RTS
passes
fails
Do
step 34
step 27
Do
step 32
step 26
step 27
Do
step 33
step 27