Configuration of Logging/Trace Function

2.2.2 LOG File Setting Items (For Logging)

The following items are set in the LOG file settings dialog box.
 Setting item
Item
File name
Application
Autostart
File output format
Logging trigger
Bit
Cycle
Time
Instruction
Bit
Time
Record limit
No. of
generations
When max.
generation
File write
(Note 1) For the bit device of file determination condition, select a bit which turns on for only one scan at the end of
scan.
(Note 2) When the logging trigger is cycle and setting per second or per minute, adjust to occur a trigger at 0 min. 0
sec. of every hour. When the unit of cycle is time, adjust to occur a trigger at 00:00:00 of every day. For details,
refer to "2.5 Operation When Setting Cycle for Logging Trigger".
2-6
Setting range
Settings
Within 32 one-byte
Enter a file name to be saved in a selected LOG number.
characters
Logging
Select Logging.
Yes: Logging operation starts when changing to the RUN
mode.
Yes / No
No: Logging operation is started or stopped by the operation
of programming tool or the F420(LOGST)
instruction/F421(LOGED) instruction in user programs.
CSV
Select CSV.
Select a condition to start logging data.
Select this for setting bit conditions as logging trigger. Press
Specify an arbitrary
the "Set" button, and select a device type and a number.
bit device.
(Note 1)
Select this for setting time as logging trigger. Input a cycle for
executing logging. (Note 2)
1 second, 2 seconds, 3 seconds, 4 seconds, 5 seconds, 6
Time data
seconds, 10 seconds, 15 seconds, 30 seconds, 1 minute, 2
minutes, 3 minutes, 4 minutes 5 minutes, 6 minutes, 10
minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 3 hours, 4
hours, 6 hours, 12 hours, 24 hours
Select this for setting clock time as logging trigger. Specify the
time for starting logging.
Clock data
Per minute, Per hour, Every day, Every week, Every month,
Every year
Trigger conditions occur by executing the F422(LOGSMPL)
-
instruction under arbitrary conditions in user programs.
Select this for setting bit conditions as file determination
Specify an arbitrary
condition. Press the "Set" button, and select a device type and
bit device.
a number.
Per minute, Per
hour, Every day,
Every week, Every
Select this for setting a fixed time as file determination
month, Every year
condition. Specify a time for determining files.
Clock data
Select this for setting the number of records as file
1 to 60000
determination condition. Specify the upper limit.
1 to 2000
Set the number of files (generations) to be saved in folder.
Stop: Stops logging.
Stop, Continue
Continue: Determines a file, and deletes the oldest file in the
PLC. After that, creates a new file.
Automatic: Once a file is determined, executes writing it into
Automatic, 1 record
an SD memory card.
unit
1 record unit: Writes data to a file every time one record is
written.