Figure 3-7 DS3/EC-1 cable routing to the left
Notes: The 12-conductor DS3/EC-1 cable is shown.
........................................................................................................................................................................................................................
4
Route the cables along the cable rack and into the terminating bay (DSX or other
terminating transmission equipment).
........................................................................................................................................................................................................................
5
Cut the cables to desired length and install the BNC connectors shipped with the cable
assemblies.
Note:
carefully to ensure a proper connection. Failure to do so may result in faulty DS3/EC-1
signals as a result of improperly installed BNC connectors.
........................................................................................................................................................................................................................
6
Connect the cables to their respective positions on the terminating equipment.See
Table 3-5, "Twenty-four cable DS3/EC-1 transmission connections" (p. 3-29)
Table 3-6, "Twelve cable DS3/EC-1 transmission connections" (p. 3-33)
connections.
Note:
the circuit pack not the backplane. There is no issue interchanging these cables on the
backplane. The DS3/EC-1 Signals are common between both cables.
........................................................................................................................................................................................................................
7
Check off the appropriate box in
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
When installing BNC connectors, follow the manufacturer's instruction