Connecting adjacent network elements
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
12
At both ends of the optical span, remove protective covers from receive and transmit
optical jumper cables and clean LC connectors.
Note:
cable. Single-mode optical fibers connecting this shelf with the far-end shelf should
not be connected to the OLIU until at least 45 seconds after an optical loopback is
removed. It may take from 15 seconds to 3.5 minutes for the FAULT LEDs to stop
flashing after the cables are connected, depending on the setting of the
OC-3/OC-12/OC-48/OC-192 signal degrade threshold.
........................................................................................................................................................................................................................
13
At both ends of the optical span, ensure that only the dual LC adapter is installed on the
OLIU (no LBO).
Note:
configurations, optical fibers extend in two different directions to make up the ring. At
each shelf (node) in the ring, the M1 OLIU will connect to the M2 OLIU in one
adjacent node, and the M2 OLIU will connect to the M1 OLIU in the other adjacent
node. Likewise, when the Alcatel-Lucent 1850 TSS-60 is interfacing with other
equipment at low-speeds (OC-3, OC-12 or OC-48) using 0x1 protection, the Function
Group slot (D, or G) 1 will connect to Main 2 on whatever shelf the Alcatel-Lucent
1850 TSS-60 is being connected to. The Function Group slot (D, or G) 2 will connect
to Main 1.
........................................................................................................................................................................................................................
14
At each end of the optical span, connect the optical fiber transmit cables to the OLIU OUT
connectors.
........................................................................................................................................................................................................................
15
At each end of the optical span, measure the optical power of the optical fiber receive
cables using an optical power meter.
............................................................................................................................................................................................................................................................
7 - 6
CAUTION
Equipment damage
The LNW38, LNW40, LNW51, LNW140, LNW380 and LNW601 OLIU circuit
packs are equipped with optics that do not meet GR-78 R9-3 requirements on
ESD susceptibility. Always use proper ESD procedures when handling these
OLIU circuit packs to avoid equipment damage.
The Alcatel-Lucent 1850 TSS-60 OLIUs require single-mode lightguide
For Alcatel-Lucent 1850 TSS-60 OC-3/OC-12/OC-48/OC-192 ring
Fiber installation
365-372-603R2.0
Issue 1 January 2009