Cable and fiber installation
............................................................................................................................................................................................................................................................
Description
Notes:
1. All the DS1 and DS3 Hybrid (28 DS1/3DS3) cable assemblies can only be used for
function group A/B.
2. Alcatel-Lucent 1850 TSS-60 connectors J5A/B(IN) and J6A/B(OUT) can only be used for
the DS1 and DS3 Hybrid (16 DS1/3DS3) cable assemblies.
3. Each Cable assembly# listed above contains two cable assemblies.
4. For Input connections use cable CA1 (DS1 and DS3 Hybrid IN) and for Output connections
use cable CA2 (DS1 and DS3 Hybrid OUT).
5. For the Coaxial cable 735A cable is used to connect Alcatel-Lucent 1850 TSS-60 to DSX-3
or another NE (50 to 350 ft. length).
6. For the Coaxial cable the 450 ft. cable (848548319) is not suitable for connection to a
DSX-3.
7. For the Coaxial cable the longest distance allowed to connect Alcatel-Lucent 1850 TSS-60
to another NE is 450ft. of length. The 550 and 655 ft. cables are for the DS1 cables only
and the Coaxial cable must be terminated at 450 ft.
8. The DS1 cables are 24 Gauge.
9. J5A/B(IN) and J6A/B(OUT) are 62 pins DSUB male type connectors.
............................................................................................................................................................................................................................................................
3 - 4 0
Cable assembly #
DS1 and DS3 hybrid cable installation
Alcatel-Lucent
1850 TSS-60
Cable length
backplane
(feet)
connections
Issue 1 January 2009