7
Repeat
equipped with LNW31 circuit packs.
........................................................................................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
LNW74 (10/100-PL) and LNW66 (10/100T) installation (optional)
Follow this procedure only if installing LNW74 (10/100-PL) or LNW66 (10/100) circuit
packs into the Alcatel-Lucent 1850 TSS-60 shelf.
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Identify the proper function group slot (D1 or
G1) where the LNW74 or LNW66 circuit pack will be installed.
Note:
function group unless the LNW141 or LNW84 VLF main OLIU is used. See the
Alcatel-Lucent 1850 Transport Service Switch (TSS-60), Release 2.0 Product
Information and Planning Guide 365-372-600R2.0 for allowed combinations.
Note:
16 10/100BASE-TX ports that are cabled from the rear of the shelf.
........................................................................................................................................................................................................................
2
Remove the LNW74 or LNW66 from the packing material.
........................................................................................................................................................................................................................
3
Place the circuit pack into the shelf (slot D1 or G1 as required). Do NOT engage the
circuit pack in the backplane connector.
........................................................................................................................................................................................................................
4
Install a 177D or LNW98 Apparatus Blank into the companion circuit pack slot (D2 or G2
as required).
Note:
provide proper air flow for cooling.
........................................................................................................................................................................................................................
5
Repeat
required) to be equipped with LNW74 or LNW66 circuit packs.
............................................................................................................................................................................................................................................................
4 - 2 4
Step 1
through
Step 6
S
F
T E P S
The LNW74 or LNW66 circuit pack can only be installed in slot 1 of any
The LNW74 has 4 100BASE-LX ports that require PTM optics in addition to
177D or LNW98 Apparatus Blanks are required in all unused slots D and G to
Step 1
through
Step 4
for each additional function group and/or growth slot to be
"Installation checklist" (p.
for each additional function group (slot D1 or G1 as
Initial circuit pack installation
I-6).
365-372-603R2.0