Cable and fiber installation
............................................................................................................................................................................................................................................................

DS3/EC-1 cable installation

Description
This section describes how to connect the DS3/EC-1 cables to the Alcatel-Lucent 1850
TSS-60 shelf and route the cables out of the bay and to the DS3/EC-1 terminating
equipment. This procedure covers both the 12 cable and the 24 cable DS3/EC-1 cables.
Perform this procedure if DS3/EC-1 cables are required.
Note:
an extension of the Alcatel-Lucent 1850 TSS-60 backplane connections. Therefore,
the IN on the Alcatel-Lucent 1850 TSS-60 backplane connects to the IN of the DSX
and the OUT of the Alcatel-Lucent 1850 TSS-60 backplane connects to the OUT of
the DSX respectively
DS3/EC-1 cable options are listed in
DS3/EC-1 transmission connections are in
transmission connections" (p. 3-29)
connections" (p.
capacity.
Note:
LNW39/LNW391 16/DS1/3/DS3 combo card in slot A/B. Instructions for cabling slot
A/B are provided in
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Obtain the DS3/EC-1 cables per
"DS3/EC-1 cable assemblies" (p. 3-20)
be used. Label the cables, indicating bay, shelf, function group (D or G) and direction (IN
or OUT of the bay) at each end.
Note:
connectors (J1D, J3D, J7G, and J9G), the additional DS3/EC-1 capacity ports (25 -
48) are cabled to the center connectors of the shelf (J2D, J4D, J8G, and J10G).
............................................................................................................................................................................................................................................................
3 - 1 6
When cabling the Alcatel-Lucent 1850 TSS-60 to a DSX, the DSX becomes
3-33). Total of two function groups fully cabled will have 96 DS3 drop
The 96 DS3 figure does not include the 3 DS3 drops available when using the
"DS1 and DS3 hybrid cable installation" (p.
The first 12/24 ports of a function unit must be cabled to the right side
Table 3-4, "DS3/EC-1 cable assemblies" (p.
Table 3-5, "Twenty-four cable DS3/EC-1
and
Table 3-6, "Twelve cable DS3/EC-1 transmission
and note the function group where each cable will
DS3/EC-1 cable installation
3-20).
3-35).
Table 3-4,
365-372-603R2.0