Stand-alone installation testing
............................................................................................................................................................................................................................................................
Result:
The FAULT LED on the circuit pack will light for several seconds then extinguish.
On the SYSCTL, the CR alarm extinguishes and the MN alarm and the NE LED will
be lit.
........................................................................................................................................................................................................................
5
Reseat the second circuit pack.
Result:
The ACTIVE LED on the second circuit pack remains off.
The FAULT LED on the second circuit pack will light for several seconds then
extinguish.
On the SYSCTL, the MN alarm extinguishes.
........................................................................................................................................................................................................................
6
Repeat this procedure for each equipped function group.
........................................................................................................................................................................................................................
7
Swap circuit packs from another function group to test any unequipped function slots.
........................................................................................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
The ACTIVE LED on the reseated circuit pack lights.
The ACTIVE LED on the first circuit pack remains on.
S
F
T E P S
Automatic protection switching and alarm test
"Installation checklist" (p.