Lnw74 And Lnw66 Testing - Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual

Transport service switch
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................

LNW74 and LNW66 testing

LNW74 (10/100), LNW66 (10/100T) TX Ethernet cabling testing
This procedure is to test the Ethernet 10/100 TX cabling from function groups D and G to
the RJ45 patch panel for use with the LNW74(10/100) or the LNW66 (10/100T)
The following cables are required to test the Ethernet cabling.
Cable
Front CIT(RS-232) Cable
(C848748869)
LAN 10BaseT Straight-through
Cable
Ethernet port assignment verification testing
........................................................................................................................................................................................................................
1
Connect the Front CIT cable between the PC and the CIT/RS 232 port of the System
Controller and login to the shelf using the serial connection and the GUI options on
WaveStar
........................................................................................................................................................................................................................
2
Identify the function groups that contain LNW74 or LNW66 circuit packs with cabling for
testing.
........................................................................................................................................................................................................................
3
Identify the RJ45 patch panel associated with the function groups identified above.
........................................................................................................................................................................................................................
4
Connect the RJ45 cable from the first RJ45 on the patch panel to the Ethernet port on your
PC.
........................................................................................................................................................................................................................
5
Watch for the link LED to light on the PC's Ethernet card or wait for 30 seconds and then
disconnect the RJ45 cable from the patch panel.
........................................................................................................................................................................................................................
6
The Fault LED will start flashing on the LNW74 or LNW66 and the GUI will alarm the
port under test and display a Critical Alarm inc.FE-LAN LOS in the Alarm List.
............................................................................................................................................................................................................................................................
6 - 2 4
®
CIT.
Length
8'-0"
As required to reach
from front of
Alcatel-Lucent 1850
TSS-60 to the RJ45
patch panel
LNW74 and LNW66 testing
Quantity
1
2
365-372-603R2.0
Issue 1 January 2009