Cable and fiber installation
............................................................................................................................................................................................................................................................
Note:
connectors (J1D, J3D, J7G, and J9G). An additional capacity of 28 DS1s, 29-56, are
used when the LNW8 circuit pack is used. The second 28 DS1s of a Function Group
are connected to the backplane (J2D, J4D, J8G, and J10G).
Note:
and J9G) are different from the cables that connect to the connectors in the center of
the backplane (J2D, J4D, J8G, and J10G). See
(p. 3-11)
Figure 3-2 DS1/E1 cable connectors
........................................................................................................................................................................................................................
3
Route the cables along the backplane and out of the bay to the DSX.
Note:
facing the rear of the shelf) and up the bay frame. See
routing to the right" (p.
of the shelf (when facing the rear of the shelf) and up the bay frame. See
"DS1/E1 cable routing to the left" (p.
Note:
to allow for access to connectors to the left or right of the center connectors depending
on whether cable dresses to the right or the left. See
to the left" (p.
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
The first 28 DS1/E1s of a Function Group must be connected to the right side
The DS1/E1 cables that connect to the right side connectors (J1D, J3D, J7G,
for more information.
Cables from J1D, J3D, J7G, and J9G route to the right of the shelf (when
3-10). Cables from J2D, J4D, J8G, and J10G route to the left
When dressing the cables from the connectors in the center of the shelf be sure
3-10).
Table 3-2, "DS1/E1 cable assemblies"
Figure 3-3, "DS1/E1 cable
3-10).
Figure 3-4, "DS1/E1 cable routing
DS1/EI cable installation
Figure 3-4,
3 - 9