Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual page 228

Transport service switch
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
Result:
NE LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-12 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
........................................................................................................................................................................................................................
4
Remove the optical fiber jumper from the OC-12 OLIU (at the LGX).
Result:
and NE LEDs should be lit on the SYSCTL circuit pack.
........................................................................................................................................................................................................................
5
If not still connected from the previous procedure. Connect the Front CIT cable between
the PC and the CIT/RS 232 port or OSI front LAN port of the System Controller and login
to the shelf using the serial/LAN connection and the GUI options on WaveStar
........................................................................................................................................................................................................................
6
Use the
........................................................................................................................................................................................................................
7
Click on the
Result:
There should be no alarm indications on the Alcatel-Lucent 1850 TSS-60 shelf.
........................................................................................................................................................................................................................
8
Remove PTM if necessary and the 15-dB LBO from OC-12 OLIU from (port 1) and plug
it into the IN connector directly below it (port 2).
Connect the fibers labeled IN and OUT from the LGX to the OLIU (port 2).
........................................................................................................................................................................................................................
9
Connect the Port 2 IN connector to the Port 2 OUT connector (at the LGX) of the OC-12
OLIU, using an optical fiber jumper cable.
Result:
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing FAULT LED should extinguish on the
OC-12 OLIU and the FAULT, MJ and NE LEDs should be lit on the SYSCTL circuit
pack.
............................................................................................................................................................................................................................................................
6 - 3 4
The FAULT LED on the OC-12 OLIU will begin flashing and the MN and IN
The FAULT LED should begin flashing on the OC-12 OLIU and only the MN
GUI
window to send the
Configuration -> Update System -> Update All.
The flashing FAULT LED should extinguish on the OC-12 OLIU.
The FAULT LED on the OC-12 OLIU will begin flashing and the MN and NE
upd-sys
command.
OC-12 low-speed testing
®
CIT.
365-372-603R2.0
Issue 1 January 2009