Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual page 153

Transport service switch
Table of Contents

Advertisement

Circuit pack installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
4
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
OC-3/OC-12/OC-48/OC-192 main OLIU installation
Follow this procedure to install the following OC-3/OC-12/OC-48/OC-192 main OLIU
circuit packs in the Alcatel-Lucent 1850 TSS-60 shelf.
LNW40 OC-3 IR
LNW140 OC-3 IR
LNW601 OC-3 LR1
LNW38 OC-12 IR
LNW51 OC-12 LR
LNW380 OC-12 LR
LNW41 OC-48 PTM
LNW84 OC-3/OC-12/OC-48 PTM
LNW402 OC-48 DWDM PTM
LNW141 OC-192 PTM
Note:
that allows the center dividers to be removed. See
TSS-60 center divider"
........................................................................................................................................................................................................................
1
Remove the first main OLIU circuit pack from the packing material.
........................................................................................................................................................................................................................
2
Identify the M1 slot on the Alcatel-Lucent 1850 TSS-60 shelf. See
"Alcatel-Lucent 1850 TSS-60 shelf" (p.
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
S
F
T E P S
CAUTION
Equipment damage
The LNW38, LNW40, LNW51, LNW2, LNW140, LNW380 and LNW601 OLIU
circuit packs are equipped with optics that do not meet GR-78 R9-3
requirements on ESD susceptibility. Always use proper ESD procedures when
handling these OLIU circuit packs to avoid equipment damage.
The LNW140, LNW141 and LNW84 require the comcode 849096334 shelf
for details on how to remove them.
"Installation checklist" (p.
Chapter 2, "Alcatel-Lucent 1850
4-9).
Initial circuit pack installation
I-6).
Figure 4-2,
4 - 1 1