Stand-alone installation testing
............................................................................................................................................................................................................................................................
Listed below are the required tools, test equipment and accessories.
Qty.
1
2
1
1
1
1
1
1
2 or 3
............................................................................................................................................................................................................................................................
II - 2
Description
Screwdriver(s)
*
Thomas & Betts
R-5648B
Crimping Tool
Paladin
Coaxial Wire
Stripper R-5648B
Replacement Paladin
Cassette R-5648B D5
Wire-Wrap Gun
R-4496A
ESD Wrist Strap
R-4987C
Ohmmeter
ITE-6379C
DS1 Error Rate Test Set
ITE-7113
DS3 Error Rate Test Set
ITE-7113
Optical Test Set (Optional)
LC-type Optical Fiber
Jumper ITE-7169
(108918269)
Comments
A screwdriver(s) with the appropriate head(s) is (are)
required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit breakers
to the OFF position.
The crimping tool and wire stripper are only required
if installing DS3 cables. The replacement cassette is
for the wire stripper tool.
The wire-wrap gun is required for terminating DS1
cable and must be able to accommodate 24-gauge
wire.
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
An ohmmeter is required to verify that the
Alcatel-Lucent 1850 TSS-60
A DS1 error rate test set is required for testing of DS1
cabling. A T-BERD 2209 or equivalent is
recommended.
A DS3 error rate test set is required for testing of DS3
cabling. A T-BERD 209 or equivalent is
recommended.
A Optical test set is required for testing of low speed
optics OC-3/12/48. An Omniber 718 or equivalent is
recommended.
Two optical fiber jumpers with LC type connectors are
required to optically loop the Alcatel-Lucent 1850
TSS-60 shelf for test purposes. In addition, for shelves
containing optical circuit packs in any of the function
unit slots, a single optical fiber jumper is required for
testing of the individual ports.
is properly grounded.
365-372-603R2.0
Issue 1 January 2009