Versiv Cabling Certification Product Family
Users Manual
Tester's accuracy
uncertainty
range
Limit

WIRE MAP Tab

The WIRE MAP tab shows the connections between the ends of
the cable under test. The tester compares the connections to the
selected Outlet Configuration to get a PASS or FAIL result.
If the wire map test fails, you can continue or stop the Autotest.
Or, you can tap SCAN ON to do the wire map test continuously
while you look for the fault. To continue the Autotest after you
correct the fault, tap SCAN OFF, then tap CONTINUE.
If you leave then return to the WIRE MAP FAIL screen, the SCAN
ON button goes away. To see the button again, tap TEST AGAIN.
You can also select the continuous wire map test as a single test
from the TOOLS menu. See "Continuous Tests" on page 58.
Figure 20 shows an example of a wire map screen. For
information on AC wire map screens, see the Technical Reference
Handbook.
The name of the outlet configuration used for the test. The
outlet configuration is a setting on the TEST SETUP screen.
The wire map of the cabling. The main tester is at the left side
of the wire map.
Tap
shows, tap it to see a message about the results, such as Bad
patch cord at remote.
50
PASS*
Figure 19. PASS* and FAIL* Results
to see information about wire map faults. If
PASS
PASS*
FAIL*
FAIL