INSPECTION OF IMMOBILIZER CONTROL MODULE AND ITS CIRCUITS
VOLTAGE INSPECTION
Immobilizer control module can be checked at wiring connectors by measuring voltage.
CAUTION:
Immobilizer control module can not be checked by itself. It is strictly prohibited to connect voltmeter
or ohmmeter to immobilizer control module with coupler disconnected from it.
NOTE:
As the battery voltage affects each terminal voltage, confirm that it is 11 V or more when ignition switch
is turned to ON position.
TERMINAL
1
–
2
V/W
3
–
4
B
5
B/W
6
W/R
7
W/B
8
–
9
W/Bl
CIRCUIT
Not used
MIL
Not used
Ground
Ignition switch signal
Data link connector
(Serial data line)
W-line
Not used
Power supply
IMMOBILIZER CONTROL SYSTEM 8G-11
NORMAL
VOLTAGE
——
0 – 1 V
MIL lights on
——
0 – 1 V
Anytime
10 – 14 V
Ignition switch at ON position
0 – 1 V
Ignition switch at OFF position
10 – 14 V
Scan tool connected
0 – 1 V
Scan tool disconnected
Scan tool connected or ignition switch
10 – 14 V
at ON position.
0 – 1 V
Scan tool disconnected and ignition
switch at OFF position.
——
10 – 14 V
Anytime
CONDITION
——
——
——