CPU Bus Unit System Setup

CIO Area Allocations
DM Area Allocations
4-2
CPU Bus Unit System Setup
Unit No.
(decimal)
0 (0)
CIO 1500 to CIO 1524
1 (1)
CIO 1525 to CIO 1549
2 (2)
CIO 1550 to CIO 1574
3 (3)
CIO 1575 to CIO 1599
4 (4)
CIO 1600 to CIO 1624
5 (5)
CIO 1625 to CIO 1649
6 (6)
CIO 1650 to CIO 1674
7 (7)
CIO 1675 to CIO 1699
Unit No.
(decimal)
0 (0)
D30000 to D30099
1 (1)
D30100 to D30199
2 (2)
D30200 to D30299
3 (3)
D30300 to D30399
4 (4)
D30400 to D30499
5 (5)
D30500 to D30599
6 (6)
D30600 to D30699
7 (7)
D30700 to D30799
To operate the FL-net Unit as a node on FL-net network, the required parame-
ters must be set in the CPU Bus Unit System Setup, part of the CPU Unit's
Parameter Areas. If any of the following items apply, then the system parame-
ters must be set.
• The Data Link function is used. The Data Link table is stored in either the
CPU Bus Unit System Setup (PLC built-in method) or the FL-net Unit Sys-
tem Setup (Unit built-in method). (Default: PLC built-in method)
• The startup method is changed. (Default: Automatic participation method)
• Message protocol confirmation is changed. (Default: Confirm)
• The broadcast method is changed. (Default: ***.***.***.255)
• The IP address is set. (Default: 192.168.250 + node number)
• The subnet mask is changed. (Default: 255.255.255.0)
• The baud rate is changed to 100 Mbps. (Default: 10 Mbps)
Newly set parameters go into effect after the FL-net Unit has been restarted
or after the CPU Unit is started again.
The settings are made in the CPU Bus Unit System Setup using the CX-FLnet
or FL-net Unit Support Software.
Note The CPU Bus Unit System Setup is located in the CPU Unit's Parameter Area,
and not in I/O Memory; parameters cannot be written using instructions or by
editing I/O Memory. The settings can be made only by using the CX-FLnet or
FL-net Unit Support Software.
Allocated words
Unit No.
(decimal)
8 (8)
9 (9)
A (10)
B (11)
C (12)
D (13)
E (14)
F (15)
Allocated words
Unit No.
(decimal)
8 (8)
9 (9)
A (10)
B (11)
C (12)
D (13)
E (14)
F (15)
Section 4-2
Allocated words
CIO 1700 to CIO 1724
CIO 1725 to CIO 1749
CIO 1750 to CIO 1774
CIO 1775 to CIO 1799
CIO 1800 to CIO 1824
CIO 1825 to CIO 1849
CIO 1850 to CIO 1874
CIO 1875 to CIO 1899
Allocated words
D30800 to D30899
D30900 to D30999
D31000 to D31099
D31100 to D31199
D31200 to D31299
D31300 to D31399
D31400 to D31499
D31500 to D31599
49