Omron CS1W-FLN22 Operation Manual page 262

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

FL-net Unit Support Software Ver. 1.6
(10) OK
Validates the changed settings and closes the window.
When the System Setup Window is next opened, the changed settings will be displayed.
(11) Cancel
Cancels the changes to the settings and closes the window.
When the System Setup Window is next opened, the settings prior to the changes will be displayed.
Note
(1) Do not assign the local node to the mapping area table.
(2) Enter 0 in the Node No. field and enter the size of the local node setup area in the Size field for the
area corresponding to that for the local node.
(3) If the settings are made for only Area 1 (or Area 2), set the offset and size for the other area to 0.
(4) The "offset" designation is the designation of how much data to receive of the data sent from a given
node (i.e., which word to begin receiving from, and how many words to receive). The number of
words from the beginning of the sent data until the beginning of the received data is called the "off-
set." The offset function can be used to receive only a portion of the data sent from a given node to
enable using the Data Link Memory Areas efficiently.
Unit Area Setup
Sets the Unit's data display and node name.
(5)
(6)
(1) Allowed min. frame interval (default: 1 (100 µs))
Sets the present minimum allowable frame interval. Valid must be selected to enable this setting. If commu-
nications errors occur, increase the value of this setting. The maximum allowable frame interval used for the
entire network is that of the node with the longest minimum allowable frame interval. The present valid value
for the network can be checked by selecting Network status (FA Link) in the Monitor field. When a baud
rate of 100 Mbps is used, set the minimum allowable frame interval to 1 ms or higher.
(2) Token watchdog timer (default: 50 ms)
Sets the timeout time for monitoring token passing between nodes. For normal usage, use the default value.
(3) Wait time of min. frame interval (default: 0)
Adds the value set here to the minimum allowable frame interval set in (1). This value is not used by the
entire network. This value is only enabled for the corresponding node.
(4) Node name
Sets the node name. Valid must be selected to enable this setting.
(5) Send
Writes set data to the Unit Area Setup Area of the specified Unit.
236
(1)
(2)
(3)
(4)
(7)
(8)
Appendix F