Command/Response Reference
Application Example
Sample Configuration
OMRON PLC
Operation
Command
114
This example shows a program with the TRANSPARENT FRAME SEND com-
mand.
The FINS 2901 command executes at the point indicate by this mark and a
transaction code is sent.
FL-net
CPU Unit
Unit
By CMND
instruction
Node number 1
Unit number 0
• Set the TRANSPARENT FRAME SEND command starting at D01000 in
the CPU Unit.
• Send the transaction code (100) and 10-byte data to node number 2.
• Store the results of the transmission starting at D02000.
[CMND
S
D
S
D01000
D
D02000 :
C
D00000
OMRON PLC/other manufacturer's PLC
FL-net
Unit
Arbitrary transaction code frame
C]
+0:
2901 Hex
+1:
4641 Hex
+2:
434E Hex
+3:
0000 Hex
+4:
004A Hex
:
+7:
0001 Hex
+8:
0002 Hex
:
+21:
0064 Hex
:
+29:
0101 Hex
+30:
004A Hex
:
+32:
Data (10 bytes long)
:
+36
First word of the stored responses
+0:
004C Hex
+1:
0004 Hex
+2:
0000 Hex
+3:
0010 Hex
Section 7-5
CPU Unit
Node number 2
(Fixed)
(Fixed)
(Fixed)
= 64 + 10 = 74 bytes
Destination node = 2
Transaction code = 100
(Fixed)
= 64 + 10 = 74 bytes
No. of command data bytes
No. of response data bytes
(including command
and response codes)
Remote (destination)
network address = 0
(local network)
Remote (destination)
node number = 0
(local node number)
Remote (destination)
unit address = 10 Hex
* Be sure to set the unit
address of the FL-net Unit