Omron CS1W-FLN22 Operation Manual page 38

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

Specifications
Comparison with Previous Models (CS1W-FLN02, CS1W-FLN12)
Model
Type
100Base-TX (10Base-T is also possible)
Switches/indica-
100M indicator provided
tors
This indicator indicates when baud rate of 100
Mbps is being used.
No rotary switch for setting the IP address.
The IP address is set using the CX-FLnet or FL-
net Unit Support Software. Either of the following
two methods can be used to set the IP address.
1. 192.168.250 + node number
2. Setup area
Data link func-
Total capacity: 8,704 words
tions
(Area 1: 512 words, Area 2: 8,192 words)
If the total number of words in Area 1 and Area 2
for a single node exceeds 7,677 words, the data
for the corresponding node will be refreshed over
two scans of the CPU Unit. The data will be split
from the 7,678th word counted from the beginning
of the combined Area 1 and Area 2.
The order of the upper and lower byte in the word
data can be swapped for each node when
exchanging data between the data link area in the
PLC and the FL-net.
Simple backup
Supported.
function
Support Soft-
CX-FLnet or FL-net Unit Support Software version
ware
1.60 or higher (CS1W-FLN22 and CJ1W-FLN22
settings cannot be made using Ver. 1.51 or lower)
Comparison between FL-net Unit Support Software
Version
FL-net Unit Support Software Ver. 1.60
New setting
Set the baud rate.
function
Set the data link data order.
Connection with
Set/monitor other nodes via the FL-net network.
PLC
Setting file
Setting files saved from Japanese version and
English version are compatible.
12
CS1W-FLN22
CJ1W-FLN22
CX-FLnet or
CS1W-FLN02/12
10Base-5 (CS1W-FLN02)
10Base-T (CS1W-FLN12)
No 100M indicator
Rotary switch provided on rear of Unit for setting
the IP address. Either of the following four meth-
ods can be used to set the IP address
1. 192.168.250 + node number
2. Rotary switch on rear of Unit.
3. Rotary switch on rear of Unit + node number
4. Setup area
Total capacity: 8,704 words
(Area 1: 512 words, Area 2: 8,192 words)
Data link tables that exceed the following condi-
tions, however, cannot be set.
Number of words in local node setup area (Area 1
and Area 2) ≤ 7,677 words.
Number of words in local node setup area (Area 1
and Area 2) + the number of words in setup area
(Area 1 and Area 2) for node with the largest setup
area size (except local node) ≤ 7,677 words
The data order cannot be changed and is fixed as
shown in the following diagram.
Common memory
MSB
LSB
PLC memory area
D15
0
Not supported.
FL-net Unit Support Software Ver. 1.51 or higher
(CS1W-FLN02 and CS1W-FLN12 settings can
also be made using Ver. 1.60 or higher)
Ver. 1.51
None (these settings are not available)
Only the local node can be set or monitored.
No compatibility between setting files saved in the
English version and Japanese version.
Section 1-5