Omron CS1W-FLN22 Operation Manual page 106

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

Setting Data Link Tables
Other Node Setup Area
Settings
Using the CX-FLnet or FL-
net Unit Support Software
80
Sequential Direction
CPU Unit
data link memory
D15
D0
ABCD
1 2 3 4
Reverse Direction
CPU Unit
data link memory
D15
D0
CDAB
3 4 1 2
This setting method is shown using the following configuration example.
The order of data link data received from node 2 is swapped in node 1. Data
swapping (reverse direction) is specified in the settings of the other node
setup area for node 1. The data received by node 3 from node 2 is refreshed
in the original order (sequential direction).
Node 1
#1
#2
#3
Receive data
"CDAB"
FL-net
common memory
MSB
LSB
ABCD
Same order as previous
1 2 3 4
CS1W-FLN02/12 FL-net Unit.
FL-net
common memory
MSB
LSB
ABCD
Order of upper and lower byte is
1 2 3 4
swapped and changed (received) in
the PLC memory.
Node 2
Node 3
#1
#1
#2
#2
#3
#3
Send data
"ABCD"
Section 5-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-fln22

Table of Contents