Omron CS1W-FLN22 Operation Manual page 155

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

Command/Response Reference
Program Example
Execute
condition
0000
A202
00
00
Execute
condition
0000
A202
00
00
(Continued next page)
@MOV(21)
• Sends a transparent frame just once when the
# 000A
Network Communications Port Enabled Flag for
D00000
port 1 and the execute condition (CIO 000000)
turn ON.
@MOV(21)
# 00CC
• Creates control data starting at D00000.
D00001
@MOV(21)
D00000
# 0002
D00002
D00001
@MOV(21)
D00002
# 0111
D00003
D00003
@MOV(21)
# 0002
D00004
D00004
@MOV(21)
# 0000
D00005
D00005
@MOV(21)
• Creates control data starting at D01000.
# 2923
D01000
@MOV(21)
# 0002
D01001
@MOV(21)
# 0002
D01002
@MOV(21)
# 0000
D01003
@MOV(21)
# 0064
D01004
• Sends the WORD BLOCK READ (unspecified
@CMND(490)
node number) command to the FL-net Unit using
D01000
the CMND(490) instruction.
D02000
D00000
@XFER(70)
• Using data that is read: Stores the 100-word data
# 0064
from D02002 (read data) starting at CIO 0000.
D02002
0000
DI F U(13)
• Turns OFF the execute condition (CIO 000000).
000000
Word
Content
00
0A
Command data length = 10
bytes
00
01
Response data length = 204
bytes
00
02
Target network address = 2
01
11
Target node address = 1
Target node number address
= 11 Hex
00
02
Response required
Communications port No.
used = 0
Retries = 2
00
00
Response monitoring time =
2 s
Section 7-5
Meaning
129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-fln22

Table of Contents