Operating Procedures
Node Status
The status of remote nodes participating in the FL-net network is shown. Data
from unmapped remote nodes can also be displayed.
Node Number
Sets the node number of the node for which the status is to be read.
Local Node Status (only when local node is specified)
Shows the status of the local node when the node set by the node number is
the local node. In this case, the same data is displayed as for the network sta-
tus.
Corresponding FL-net Standard Flag Names
CX-FLnet
Common memory setting range error
Duplicate node number notification
Token monitoring timeout error
Frame standby error
Node Status
Shows the participation status of the node.
FA Link Status
Shows the network status of the node set by the node number.
Upper Layer Status
Shows the upper layer status.
Status
RUN
STOP
Status
NORMAL
WARNING
ALARM
Initialization Error Flag
Duplicate Node Number Flag
Token Monitoring Timeout Flag
Reception Standby Flag
Meaning
CPU Unit is running (RUN/MONITOR mode).
CPU unit is stopped (PROGRAM mode).
Meaning
CPU Unit is normal.
Non-fatal error has occurred.
Fatal error has occurred
Section 11-2
FL-net standard flag name
185