Omron CS1W-FLN22 Operation Manual page 185

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

Troubleshooting Procedures
Main response
Sub-response code
code
Value
Meaning
Value
02
Remote
00
node error
01
05
04
04: Not exe-
01
cutable
(Service not
supported.)
05
01
02
03
04
Check point
Meaning
Command
Command data
data error
Remote
IP address
node not in
table, IP router
network
table
Response
Response to
timeout
CONTROLLER
STATUS READ
FINS command
Control data in
instruction
Read error log
Unsup-
Command code An undefined command
ported
command
FINS header
frame length
Routing
Routing tables
table set-
ting error
Routing
Routing tables
tables not
registered
Routing
Routing tables
table error
Too many
Network config-
relays
uration
Probable cause
An error response was
returned for the com-
mand executed at the
remote node.
IP address of remote
node not set correctly in
IP address table or IP
router table.
Message packet was cor-
rupted by transmission
error.
Response monitor time
interval too short.
The transmission frame
may be corrupted or the
internal reception buffer
is full.
has been used.
A short frame (4 bytes) is
being used for the FINS
header frame.
Remote node address is
not set in the routing
tables.
Cannot determine desti-
nation because routing
tables have not been cre-
ated.
Routing table error
The maximum number of
network levels (3) was
exceeded in the com-
mand.
Section 10-4
Remedy
Check the command data and
status of the remote node.
Set IP address of remote
node into IP address table
and, if internetwork transmis-
sion is required, into the IP
router table.
Increase the number of trans-
mit retry attempts.
Increase the value for the
response monitor time param-
eter.
Check the error log and cor-
rect as required.
Check the command code.
Check the FINS header frame
length. The FL-net Unit does
not support short headers.
Set the destination address in
the routing tables.
Set routing tables at the local
node, remote node, and any
relay nodes.
Set the routing tables cor-
rectly.
Redesign the network or
reconsider the routing table to
reduce the number of relay
nodes in the command. Com-
munications are possible on
three network levels, including
the local network.