System Setting - CPU Bus Unit Setup Area
Any of several different operating parameters can be selected depending on the system, but the explanation is
provided here in terms of simple operating conditions.
(10)
(1) FA Link mapping table method (Default: PLC built-in method)
Selects the method (PLC built-in method or FA Link Unit built-in method) for storing the FA Link mapping
table.
Normally the default should be selected.
(2) FA Link startup method (Default: Auto-participating method)
Selects the method (auto-participating or manual-participating) for starting the FA Link.
Normally the default should be selected.
(3) Confirm message protocol (Default: Confirmed)
Selects the protocol (confirmed or unconfirmed) for when messages are used.
Select "Confirmed" for a network with OMRON FL-net Units only.
Select "Unconfirmed" for a network in which units from other manufacturers are connected.
(4) Broadcast type (Default: ***.***.***.255)
Selects the broadcast type (***.***.***.255, C255.255.255.255).
Normally the default should be selected.
(5) IP address set method (Default: 192.168.250 + Node No.)
Selects the IP address setting method (192.168.250 + Node No., Unit rear rotary SW, Unit rear rotary SW +
Node No., or Setup area).
Normally the default should be selected.
When using CS1W-FLN22 or CJ1W-FLN22, select either 192.168.250 + Node No or Setup area.