Command/Response Reference
Mode Setting (Response)
First byte
15
14
13
12
11
10
1) System type
108
The mode set in the system setup is returned.
Second byte
9
8
7
6
5
4
3
2) IP
address
setting
1. System Type
Bits 12 to 15 show the type of Unit.
Bit
15
14
0
0
Others
2. IP Address Setting
These bits provide details about the type of IP address settings.
Bit
7
6
0
0
Operates with the IP address switch setting on the back of the Unit.
1
0
Operates with the IP address switch setting on the back of the Unit
and the node address switch setting on the front of the Unit.
0
1
Operates with the CPU Bus Unit system setting that is set through the
CX-FLnet or FL-net Unit Support Software.
1
1
Operates with the default setting
(192.168.250.node_address_switch_setting).
3. FA Link Allocation Table Storage Method
This bit provides details about where the data link (FA link allocation) table
is stored.
Bit
0
0
Store in CPU Unit
Stores the data link tables (FA link allocations) in the System Bus Unit setup
area of the CPU Unit.
1
Store in FL-net Unit
Stores the data link tables (FA link allocations) in the FL-net (Ver. 2.00) Unit
EEPROM.
2
1
0
3) FA Link allocation table storage method
4) FA Link startup method
5) Message procedure check
6) Broadcast format
7) Data sending order (sequential/reverse direction)
8) Baud rate
13
12
0
1
FL-net Unit
Parameter error
Description
Section 7-5
Description
Description