Command/Response Reference
Command
Response
[CMND
S
D
C]
S
D01000
D
D02000
C
D00000
D02000
+0
:2902 Hex
:First word of the stored responses
+0
:0002 Hex
+1
:004E Hex
+2
:0000 Hex
+3
:0010 Hex
+4
:0000 Hex
+5
:0000 Hex
+0
:2902 Hex
+1
:0000 Hex
:
+4
:0001 Hex
+5
:004A Hex
+6
:0001 Hex
+7
:0002 Hex
:
+22
:0064 Hex
:
+34
:Data (10-bytes long)
:
+38
Section 7-5
No. of command data bytes
No. of response data bytes
(including command
and response codes)
Remote (destination)
network address 0
(local network)
Remote (destination)
node number 0
(local node number)
Remote (destination)
unit address 10 Hex
* Be sure to set the
unit address of the FL-net
(Ver. 2.00) Unit to the
Unit number + 10 Hex.
Response required,
communication port no. 0,
number of retries 0
Response monitoring time
(default: 2 s)
Response code
(completed normally)
(Undecided)
(Fixed)
=64+10=74 bytes
Destination node number 2
(Undecided)
Transaction code 100
(Undecided)
119