Omron CS1W-FLN22 Operation Manual page 142

100base-tx, sysmac cs / cj series, fl-net units
Table of Contents

Advertisement

Command/Response Reference
Execute
condition
0000
A202
00
00
Execute
condition
0000
A202
00
00
116
• Creates control data (command code/FA message
@MOV(21)
header) starting at D01000. Parameters that are
# 2901
generated automatically by the FL-net Unit do not
D01000
have to be set.
@MOV(21)
Word
#4641
D01000
D01001
D01001
@MOV(21)
D01002
#434E
D01003
D01002
D01004
@MOV(21)
D01007
# 0000
D01008
D01003
D01021
@MOV(21)
D01029
# 004A
D01030
D01004
@MOV(21)
# 0001
D01007
@MOV(21)
# 0002
D01008
@MOV(21)
# 0064
D01021
@MOV(21)
# 0101
D01029
@MOV(21)
# 004A
D01030
• Creating send data: Stores the 10-byte long data
@XFER(70)
(5 words) from word 0000 starting at D01033 (FA
# 0005
0000
message data).
D01033
• Sends the TRANSPARENT FRAME SEND com-
mand to the FL-net Unit using the CMND(490)
@CMND(490)
instruction.
D01000
• Turns OFF execute condition 000000.
D02000
D00000
DIFU(13)
000000
Content
Meaning
29
01
Command code
46
41
H_TYPE Upper = (Fixed value)
43
4E
H_TYPE Lower = (Fixed value)
00
00
TFL Upper = (Fixed value)
00
4A
TFL Lower = 74 bytes
00
01
DNA Upper = (Fixed value)
00
02
DNA Lower = 2
00
64
TCD = 100
01
01
CBN/TBN = (Fixed value)
00
4A
BSIZE = 74 bytes
Section 7-5