2
Introduction
2.6
Remote Desktop Manager (option 133)
Setting
Connection name
Restarting after end of
connection
Automatic starting upon
login
Add to favorites
Move to the following
workspace
Release USB mass memory
Computer
User name
Password
Windows domain
Full screen mode or user-
defined window size
Entries in the Advanced
options area
92
Meaning
Name of the connection in the Remote Desktop Manager
Behavior with terminated connection:
Always restart
Never restart
Always after an error
Ask after an error
Connection automatically established during control power-up
Connection icon in the task bar:
Double click with left mouse button: The control starts the
connection
Single click with left mouse button: The control changes to the
desktop of the connection
Single click with right mouse button: The control displays the
connection menu
Number of desktop for the connection, whereby desktops 0 and 1
are reserved for the NC software
Enable access to connected USB mass memory
Host name or IP address of the external computer
Name of the user
User password
Domain of the external computer
Size of the connection window
Available only to authorized specialists
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2015
Input
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Optional