Parameter settings
NC stop during tool measurement
True: When the breakage tolerance is exceeded the NC program is stopped
False: The NC program is not stopped
Modification of tool table during tool check and measurement
AdaptOnMeasure: Table modified after tool measurement
AdaptOnBoth: Table modified after tool check and measurement
AdaptNever: Table not modified after tool check and measurement
Configuring a round stylus
TT140_1
Coordinates of stylus center
[0]: X coordinates of stylus center referenced to machine datum
[1]: Y coordinates of stylus center referenced to machine datum
[2]: Z coordinates of stylus center referenced to machine datum
Safety clearance above stylus for pre-position
0.001 to 99,999.9999 [mm]: Safety clearance in tool axis direction
Safety zone around stylus for pre-positioning
0.001 to 99,999.9999 [mm]: Safety clearance in the plane vertically to the tool axis
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2015
Machine-specific user parameters 18.1
18
615