Software Flow Control; Auto Baud Rate Detection - Samsung S3C2501X User Manual

32-bit risc microprocessor
Table of Contents

Advertisement

SERIAL I/O (HIGH-SPEED UART)
RXD
RTS
CTS
RXD
Pin Signal
DCD
RXD
Internal
Signal

11.4.3 SOFTWARE FLOW CONTROL

Software can control High-Speed UART by control characters. High-Speed UART compares received data with
control characters, and if they are identical, it sets "1" at state bit (CCD:HUSTAT[5]) and generates interrupt
which masked by Interrupt enable register.

11.4.4 AUTO BAUD RATE DETECTION

To use Auto Baud Rate Detection, Set ABB(AutoBaud rate Boundary), ABT(AutoBaud rate Table) Register and
Auto Baud Detect bit(AUBD:HUCON[6]), When RXD level is low, High-Speed UART counts low-level of start
singal ( 'A' ) and rewrites counting value of low-level by comparing ABB, ABT Register. This automatically
corrects Baud Rate(CNT0 and CNT1)
11-26
Start Bit
Figure 11-17. Normal Received Rx Data
Start Bit
Start Bit
Figure 11-18. DCD Lost During Rx Data Receive
Data Region
Data Region
S3C2501X
Stop Bit
Stop Bit

Advertisement

Table of Contents
loading

Table of Contents